Amalgam Removal Systems |
|
| |
SolmeteX | AB Dental Trends
|
RebecSolutions
| Capsule
Technologies Inc. |
|
| |
|
Capsule
Technologies Inc. |
| |
|
|
ASDEX AS-9 Amalgam
Separator
(ISO 11143
Certified ISO Rated 99.0%)

(2000D & MBK-1)
Single
Chairside System Portable System/Mobile System
| Item # |
Description |
Price |
| AS10S |
Complete
System
Includes: 1
Manifold Head Assembly, 1-Mount Bracket, 1-Replacement
Separator
(as-10) |
$233.00 |
| 2000D |
Manifold
Head Assembly |
$104.00 |
| MBK-1 |
Mounting
Bracket |
$30.00 |
| AS-10 |
Replacement Separator |
$90.00 |
Mounting Space Required:
5"x14"
Average Life: 4-8 Months
Flow Rate: 1L/MN ISO Rated: 99.0%
Replacement Schedule: When vacuum is depleted to
mouthpiece or 1 year.
Dispose in accordance with any and all local, State &
Government guidelines. |
Central Vacuum System
2-4 Chairs
| Item
# |
Description |
Price |
| AS20S |
Complete System
Includes:
1-Manifold Head Assembly, 1-Mounting Bracket,
1-Replacement Separator (as-20) |
$332.00 |
| 2000D |
Manifold Head Assembly |
$104.00 |
| MBK-1 |
Mounting Bracket |
$30.00 |
| AS-20 |
Replacement Separator |
$198.00 |
Mounting Space
required 5"x 24"
Average Life: 4-8 Months
Flow Rate: 1L/MN ISO Rated: 99.0%
Replacement Schedule: When vacuum is depleted to
mouthpiece or 1 year.
Dispose in accordance with any and all local, State
& Government guidelines. |
|
Installation Instructions for
AS-9 Amalgam Separator
Central
Vacuum System: 2-4 chairs
-
Install the ASDEX
Manifold Head Assembly (2000D) in a location as
close to vacuum pump as practical.
-
The system needs to
be mounted in a vertical position.
-
Do not remove ty-wrap
from manifold until manifold installation is
complete.
-
Use mounting bracket
(MBK-1) to mount manifold.
-
Out port (note arrow)
goes to vacuum pump, in port (note arrow) goes to
vacuum line leading to dental operatory.
-
Remove and save the
two disposal caps from the ASDEX Separator.
-
Before installing
ASDEX AS-20 Amalgam Separator remove ty-wrap from
manifold head assembly.
Chair Side: Single
Chair
-
Install the ASDEX Manifold Assembly near chair.
-
The system needs to
be mounted in a vertical position.
-
Do not remove ty-wrap
from manifold until manifold installation is
complete.
-
Use mounting bracket
(MBK-1) to mount manifold.
-
Out port (note arrow)
goes to vacuum pump, in port (note arrow) goes to
mouthpiece.
-
Remove and save the
two disposal caps from the ASDEX Separator.
-
Before installing
ASDEX AS-20 Amalgam Separator remove ty-wrap from
manifold head assembly
|
Click Here for Information of Approved Amalgam Recyclers. |
|
| |
|
|
| |
|
|